Abstract Intraoperative electrocorticography (ECoG) captures neural information from the surface of the cerebral cortex during surgeries such as resections for intractable epilepsy and tumors. Current clinical ECoG grids come in evenly spaced, millimeter‐sized electrodes embedded in silicone rubber. Their mechanical rigidity and fixed electrode spatial resolution are common shortcomings reported by the surgical teams. Here, advances in soft neurotechnology are leveraged to manufacture conformable subdural, thin‐film ECoG grids, and evaluate their suitability for translational research. Soft grids with 0.2 to 10 mm electrode pitch and diameter are embedded in 150 µm silicone membranes. The soft grids are compatible with surgical handling and can be folded to safely interface hidden cerebral surface such as the Sylvian fold in human cadaveric models. It is found that the thin‐film conductor grids do not generate diagnostic‐impeding imaging artefacts (<1 mm) nor adverse local heating within a standard 3T clinical magnetic resonance imaging scanner. Next, the ability of the soft grids to record subdural neural activity in minipigs acutely and two weeks postimplantation is validated. Taken together, these results suggest a promising future alternative to current stiff electrodes and may enable the future adoption of soft ECoG grids in translational research and ultimately in clinical settings.
Publication scientifique
MRI‐Compatible and Conformal Electrocorticography Grids for Translational Research
Autres publications de la plateforme
The e-Flower: A hydrogel-actuated 3D MEA for brain spheroid electrophysiology
Martinelli, Eleonora; Akouissi, Outman; Liebi, Luca; Furfaro, Ivan; Maulà, Desirée; Savoia, Nathan; Remy, Antoine; Nikles, Laetitia; Roux, Adrien; Stoppini, Luc; Lacour, Stéphanie P.
Science Advances
Wireless, battery-free, and real-time monitoring of water permeation across thin-film encapsulation
Mariello, Massimo; Rosenthal, James Daniel; Cecchetti, Francesco; Gao, Mingxiang; Skrivervik, Anja K.; Leterrier, Yves; Lacour, Stéphanie P.
Nature Communications
Optical Monitoring of Water Side Permeation in Thin Film Encapsulation
Wu, Kangling; Mariello, Massimo; Leterrier, Yves; Lacour, Stéphanie P.
Advanced Materials
A low-profile electromechanical packaging system for soft-to-flexible bioelectronic interfaces
Fallegger, Florian; Trouillet, Alix; Coen, Florent-Valéry; Schiavone, Giuseppe; Lacour, Stéphanie P.
APL Bioengineering
Deployment of an electrocorticography system with a soft robotic actuator
Song, Sukho; Fallegger, Florian; Trouillet, Alix; Kim, Kyungjin; Lacour, Stéphanie P.
Science Robotics
Subdural Soft Electrocorticography (ECoG) Array Implantation and Long-Term Cortical Recording in...
Fallegger, Florian; Trouillet, Alix; Lacour, Stéphanie P.
Journal of Visualized Experiments
Journal de publication
Advanced Science
Auteurs:
Fallegger, Florian; Schiavone, Giuseppe; Pirondini, Elvira; Wagner, Fabien B.; Vachicouras, Nicolas; Serex, Ludovic; Zegarek, Gregory; May, Adrien; Constanthin, Paul; Palma, Marie; Khoshnevis, Mehrdad; Van Roost, Dirk; Yvert, Blaise; Courtine, Grégoire; Schaller, Karl; Bloch, Jocelyne; Lacour, Stéphanie P.
Date de publication:
Plateforme:
Études récentes de la plateforme

Réparer les lésions de la moelle épinière
Cibler les neurones qui rétablissent la marche
À l'aide de la transcriptomique unicellulaire et spécifique à la projection, les scientifiques ont découvert une population...

Restaurer le mouvement après une paralysie
Stimulation électrique de la moëlle épinière
Un réseau d’électrodes implantables, connecté à un stimulateur implanté, délivre des impulsions électriques aux différents nerfs spinaux.
Chaque...

Suivi de la dopamine dans la maladie de Parkinson
Détection de la dopamine grâce à des biosenseurs à base d’ADN
Une approche innovante utilise des brins d’ADN artificiellement conçus, appelés aptamères, qui capturent...