Publication scientifique

AccueilVariability and reproducibility of multi-echo T2 relaxometry: Insights from multi-site, multi-session and...

Variability and reproducibility of multi-echo T2 relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions

Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T 2 relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T 2 relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model’s parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space ( T 2 I E ) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T 2 relaxometry dataset. To this end, we evaluated three different techniques for estimating the T 2 spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that T 2 I E is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92.

Autres publications de la plateforme

Characterising the Diffusion Functional Signature of Negative BOLD With Interleaved TMS...

De Riedmatten, Inès; Spencer, Arthur P. C.; Martuzzi, Roberto; Rochas, Vincent; Pérot, Jean‐Baptiste; Szczepankiewicz, Filip; Jelescu, Ileana O.
Human Brain Mapping
Plateforme d’Imagerie par Résonance Magnétique (IRM)

Aberrant cerebrovascular reactivity presents as an early biomarker of psychosis susceptibility...

Delavari, Farnaz; Moia, Stefano; Forrer, Silas; Sandini, Corrado; Kojovic, Nada; Pascucci, Alessandro; Lacour, Clémence; Eliez, Stephan; Van De Ville, Dimitri
Translational Psychiatry

Real-time reinforcement for human-machine interface control

Vassiliadis, Pierre; Pinheiro, Daniel Leal; Fleury, Lisa; Zenon, Alexandre; Esparza-Iaizzo, Martín; Ingster, Abigaïl; Micera, Silvestro; Shokur, Solaiman; Hummel, Friedhelm C.
Neuron

Developmental Alterations in the Diffusion Tensor Imaging Analysis Along the Perivascular...

Pascucci, Alessandro; Forrer, Silas; Sandini, Corrado; Mancini, Valentina; Alemán-Gómez, Yasser; Eliez, Stephan; Delavari, Farnaz
Biological Psychiatry Global Open Science

How Much Does Motion Matter? Evaluating the Motion Robustness of pTx...

Philippe, Jocelyn; Pato Montemayor, Natalia; Romanin, Ludovica; Sleight, Emilie; Klauser, Antoine; Di Noto, Tommaso; Bacha, Lina; Maréchal, Bénédicte; Herrler, Jürgen; Liebig, Patrick A.; Heidemann, Robin M.; Thiran, Jean‐Philippe; Hilbert, Tom; Piredda, Gian Franco; Yu, Thomas
Magnetic Resonance in Medicine

Linguistic pitch is hierarchically encoded in the right ventral stream

Oderbolz, Chantal; Orpella, Joan; Meyer, Martin
Communications Biology

Journal de publication

Frontiers in Radiology

Auteurs:

Fischi-Gomez, Elda; Girard, Gabriel; Koch, Philipp J.; Yu, Thomas; Pizzolato, Marco; Brügger, Julia; Piredda, Gian Franco; Hilbert, Tom; Cadic-Melchior, Andéol G.; Beanato, Elena; Park, Chang-Hyun; Morishita, Takuya; Wessel, Maximilian J.; Schiavi, Simona; Daducci, Alessandro; Kober, Tobias; Canales-Rodríguez, Erick J.; Hummel, Friedhelm C.; Thiran, Jean-Philippe

Date de publication:

Plateforme:

Études récentes de la plateforme

Neuro-ingénieriePsychologie et neurosciences cognitives

Quand le cerveau s’éteint à l’IRM : un signal plus complexe...

Quand une diminution du signal reste difficile à interpréter L’imagerie par résonance magnétique fonctionnelle (IRMf) permet de repérer les régions du cerveau qui réagissent...
Plateforme d’Imagerie par Résonance Magnétique (IRM)Plateforme M/EEG & Neuromod (MEG)

La connaissance comme récompense

Comparaison de différents types de récompenses Les participants prennent part à une tâche comprenant trois types de récompenses, de valeur élevée ou faible : -...
Plateforme d’Imagerie par Résonance Magnétique (IRM)Plateforme M/EEG & Neuromod (MEG)

Réseaux cérébraux de la mémoire dans l’épilepsie

Cartographie multimodale des réseaux cérébraux Combinaison de l'EEG, de l'IRM à champ ultra-élevé et de modèles animaux Ce projet vise à identifier les marqueurs...
Plateforme d’Imagerie par Résonance Magnétique (IRM)Plateforme M/EEG & Neuromod (MEG)